Oil Immersed Silicon Steel Transformer Core For Energy Storage Booster Stations
Basic Properties
Trading Properties
| Highlight | oil immersed silicon steel transformer core,oil immersed current transformer core |
||
|---|---|---|---|
The oil-immersed transformer core is the core magnetic circuit component of oil-filled power transformers. It forms a closed magnetic path to transmit magnetic flux and realizes electromagnetic induction and power conversion between primary and secondary windings. It is mainly stacked with high-grade CRGO grain-oriented silicon steel sheets by step-lap technology. Each sheet is coated with inorganic insulating film to suppress eddy current loss. The core assembly is fixed by clamping frames and pull plates, equipped with cushioning structures to reduce vibration and noise. The core operates immersed in transformer oil. The oil acts as both cooling medium and insulation medium. Strictly manufactured in accordance with IEC 60076 international standards, this core directly determines the no-load loss, excitation current, temperature rise and overall service life of the oil-immersed transformer.
- Power grid & substations: municipal power grid, step-up & step-down substations, rural power renovation projects
- Heavy industry: steel plants, mines, cement plants, large manufacturing factories
- New energy: solar power stations, wind farms, energy storage booster stations
- Oil & gas, port and railway power transmission systems
- Large commercial power supply, industrial distribution and long-distance power transmission projects
- Material: High-grade CRGO grain-oriented silicon steel (0.23 / 0.27 / 0.30mm), high-quality insulating coating, anti-rust protective paint
- Magnetic Performance: High magnetic permeability, low hysteresis loss, stacking factor ≥0.97, stable flux density design, excellent no-load characteristics
- Structure: Step-lap stacked structure; rigid clamping system with cushion pads; good mechanical strength, anti-vibration and anti-loose
- Cooling & Insulation: Designed for oil immersion cooling; transformer oil provides heat dissipation and insulation together
- Reliability: Mature structure, stable performance, convenient for routine inspection and maintenance, adaptable to continuous long-time operation
| No-load loss and no-load current of oil-immersed transformer core | ||||||||||
| Rated Capacity kVA |
S13(GB) | S20(GB) | S22(GB) | EU Tier 1 | EU Tier 2 | |||||
| P₀ W | I₀ % | P₀ W | I₀ % | P₀ W | I₀ % | P₀ W | I₀ % | P₀ W | I₀ % | |
| 50 | 100 | 1.3 | 90 | 1.17 | 80 | 1.1 | 90 | 1.17 | 81 | 1.1 |
| 100 | 150 | 1.1 | 135 | 0.99 | 120 | 0.94 | 145 | 0.99 | 130 | 0.94 |
| 160 | 200 | 1 | 180 | 0.9 | 160 | 0.85 | 210 | 0.9 | 189 | 0.85 |
| 250 | 290 | 0.9 | 260 | 0.81 | 230 | 0.77 | 300 | 0.81 | 270 | 0.77 |
| 315 | 340 | 0.9 | 305 | 0.81 | 270 | 0.77 | 360 | 0.81 | 324 | 0.77 |
| 400 | 410 | 0.8 | 370 | 0.72 | 330 | 0.68 | 430 | 0.72 | 387 | 0.68 |
| 500 | 480 | 0.8 | 430 | 0.72 | 385 | 0.68 | 510 | 0.72 | 459 | 0.68 |
| 630 | 570 | 0.6 | 510 | 0.54 | 460 | 0.51 | 600 | 0.54 | 540 | 0.51 |
| 800 | 700 | 0.6 | 630 | 0.54 | 560 | 0.51 | 650 | 0.54 | 585 | 0.51 |
| 1000 | 830 | 0.6 | 745 | 0.54 | 665 | 0.51 | 770 | 0.54 | 693 | 0.51 |
| 1250 | 970 | 0.5 | 870 | 0.45 | 780 | 0.42 | 950 | 0.45 | 855 | 0.42 |
| 1600 | 1170 | 0.5 | 1050 | 0.45 | 940 | 0.42 | 1200 | 0.45 | 1080 | 0.42 |
| 2000 | 1360 | 0.4 | 1225 | 0.36 | 1085 | 0.34 | 1450 | 0.36 | 1305 | 0.34 |
| 2500 | 1600 | 0.4 | 1440 | 0.36 | 1280 | 0.34 | 1750 | 0.36 | 1575 | 0.34 |
Quality assurance runs through the entire production process. All electrical tests are performed in accordance with IEEE,IEC standards; Process control is jointly executed by the production team and IPQC (In-Process Quality Control). Through routine inspections and regular sampling verifications, we ensure stable and reliable product quality.