Basic Properties
Trading Properties
| Phase: | Three Phase | Product Type: | Corrosion-Protected Three-Phase Oil-Immersed Transformer |
|---|---|---|---|
| Rated Capacity: | 30-2500 KVA | Primary Voltage: | 6kV/12kV/20kV/22kV Tapped Primary |
| Secondary Voltage: | 0.4kV/0.415kV Or Customized | Tap Range: | ±2×2.5% (Off-circuit) |
| Vector Group: | Dyn11 Or Yyn0 | Impedance Voltage: | 4%-6% (Customized) |
| Cooling Method: | ONAN | Coating System: | Epoxy Zinc-rich Primer + Two Top Coats, C5 Rated |
| Core Material: | CRGO Silicon Steel | Insulation Fluid: | Mineral Oil Or As Specified. |
| Frequency: | 50HZ Or 60 Hz | Winding Material: | Copper Or Aluminum |
| Application: | Ports, Desalination Plants And Coastal Projects | Warranty: | Two Years |
| Highlight | 10kv oil immersed transformer,10kv oil filled distribution transformers,12kv oil immersed transformer |
||
Corrosion-Protected Three-Phase Oil-Immersed Transformer with 10kV 12kV 20kV Tapped Primary
Coastal and humid export projects punish ordinary paint systems long before the transformer itself reaches end of life. This corrosion-protected three-phase oil-immersed transformer is built for those sites, with a multi-layer coating applied over a shot-blasted surface, stainless steel fasteners throughout, and sealed terminal boxes that keep salt-laden air away from live parts. The primary winding is tapped for 10kV, 12kV and 20kV service, so the same corrosion package can be quoted into ports, desalination plants and seaside resorts across several grid standards.
Key Features- Corrosion protection package: Shot blasting to Sa2.5 followed by an epoxy zinc-rich primer and two top coats gives a coating system rated for C5 coastal atmosphere.
- Three voltage classes in one winding: Tapped primary sections for 10kV, 12kV and 20kV remove the need for a special design per market and shorten quotation lead time.
- Three-phase stability under unbalanced load: A symmetrical three-limb core holds neutral current within design limits when single-phase loads are unevenly spread across phases.
- Humidity-proof insulation: Vacuum oil impregnation after coil drying keeps moisture content in the insulation system low, protecting dielectric strength in high-humidity service.
- Maintenance-friendly layout: Externally mounted oil temperature indicator, pressure relief device and sampling valve allow inspection without breaking the seal.
| Parameter | Specification |
|---|---|
| Phase | Three Phase |
| Rated Capacity | 30 kVA to 2500 kVA |
| Rated Voltage | 6kV~35kV |
| Tap Range | Plus or minus 2 x 2.5 percent off-circuit |
| Vector Group | Dyn11 or Yyn0 |
| Impedance Voltage | 4 percent to 6 percent customized |
| Coating System | Epoxy zinc-rich primer plus two top coats, C5 rated |
| Core Material | CRGO silicon steel |
| Winding material | Copper or Aluminum |
| Insulation Fluid | Mineral Oil or as specified. |
| Frequency | 50 Hz / 60 Hz |
| Warranty | Two Years |
Port terminals, desalination and water treatment plants, seaside hotel and resort complexes, offshore-support onshore facilities, and chemical or paper plants where airborne humidity and salt accelerate corrosion. The tapped primary suits projects on 11kV, 13.8kV and 22kV nominal systems once the tap setting is matched to the local feeder voltage.
Packaging & Quality AssuranceTanks are wrapped in barrier foil with desiccant and shipped on timber skids with the coating protected by edge padding. Tests include winding resistance, ratio and vector group, no-load and load loss, impedance voltage, applied and induced voltage withstand, plus a coating thickness check at three points per tank. Reports cover routine electrical tests, coating measurements and an oil dielectric strength certificate before filling.
Contact Person: Ms. Floria Lee
Tel: +8613868730604