JP Distribution Cabinet Reactive Power Reactive Current Ratings 10 KVA To 630 KVA
Basic Properties
Trading Properties
| Product Type: | Distribution Cabinet | Product Series: | JP |
|---|---|---|---|
| Rated Capacity: | 10/20/30/50/63/80/100/125/160/200/250/315/400/500/630(kVA); | Rated Voltage: | 400V |
| Frequency: | 50Hz | Capacitor Stages: | Typically Available In 2, 3, 4, Or 5 Stages; Customized Configurations Are Available |
| Feeder Circuits: | Typically Configured With 2 Feeder Circuits, Each Rated At 80%–100% Of The Total Transformer Capacity; Customized Configurations Are Available Upon Request. | Compensation Methods: | Cyclic Switching, Coded Switching, And Automatic Switching With Fuzzy Control. |
| Control Parameters:: | Reactive Power Or Reactive Current. | Fastest Response Time: | ≤20ms |
| Highlight | distribution cabinet reactive power,reactive power cabinet power distribution,reactive current distribution cabinet |
||
The JP Series Distribution Cabinet is Hangen's low-voltage reactive power compensation and distribution unit, engineered to keep power factor high and network losses low in commercial, industrial and utility installations. Running at 50Hz and 400V, it merges feeder distribution with automatic capacitor compensation in a single enclosure, releasing transformer capacity for productive load while stabilising voltage at the point of use. With a capacity span from 10 kVA to 630 kVA, one platform covers small workshops through to large plants.
Commissioning is straightforward: wiring diagrams and controller settings accompany every unit, and our technical team assists with capacity, stage and switching-mode selection. Minimum order quantity is one unit, payment terms are L/C or T/T, and delivery as well as packaging are negotiated per order.
Product Advantages| Product Type | Distribution Cabinet |
|---|---|
| Product Series | JP |
| Frequency | 50Hz |
| Rated Capacity | 10/20/30/50/63/80/100/125/160/200/250/315/400/500/630(kVA) |
| Rated Voltage | 400V |
| Feeder Circuits | Typically configured with 2 feeder circuits, each rated at 80%–100% of the total transformer capacity; customized configurations are available upon request. |
| Capacitor Stages | Typically available in 2, 3, 4, or 5 stages; customized configurations are available |
| Compensation Methods | Cyclic switching, coded switching, and automatic switching with fuzzy control. |
| Control Parameters | Reactive power or reactive current. |
| Fastest Response Time | ≤20ms |
| Brand Name | Hangen |
| Certification | ISO/CE |
| Place of Origin | China |
Contact Person: Ms. Floria Lee
Tel: +8613868730604